Wyckoff Mapper
Wyckoff accumulation and distribution ranges mapped bar by bar from price and volume, each event marked once it is confirmed, with the range's phase and an event list for the latest range.
mdtWyckoffRanges and events, drawn once confirmed.
Relative volume as the input
Each bar's volume against its norm: the mean volume at the same time of day over the past 20 sessions on minute and second charts, a rolling 50-bar mean on range, tick and day charts. On minute charts the norm starts from the 1-minute days before the chart, so it is ready from the first bars.
A climax after an extended move
Once the close has travelled far enough over the bars behind it, a bar making a new extreme on wide range and heavy volume is the selling or buying climax. The automatic reaction, the first confirmed swing against it, fixes the range from climax to reaction. Until then the climax waits as a dashed line.
The events, in order
Preliminary support or supply, secondary test, spring or upthrust, test, sign of strength or weakness, back-up, and last point of support or supply. Each is recorded at the bar that confirms it and labelled beyond the candles. By default a spring counts only after the secondary test, the textbook order.
Phases A to E
A from the climax to the first secondary test, B after it, C the spring and test, D from the sign of strength to the back-up and last point of support, E the markup or markdown. A strip under the range's bars carries the letters; a tag above names accumulation or distribution.
How a range ends
It ends in phase E on a close beyond the range by a set share of its height, fails on a close beyond the climax (after a spring, beyond the spring's extreme), or expires after a set number of bars. A failed or expired box turns dashed and stays on the chart.
Every threshold a setting
The extended move, climax range and volume, test zones and volumes, sign-of-strength distance and the rest are settings and rebuild live. Range and Renko bars are judged on volume alone, since every bar has the same spread; volume bars are refused.
What it looks like in a session.
Wyckoff's range schematic, read by the bar.
Richard Wyckoff described how a trend ends: a climax on heavy volume, a reaction, then a range in which the earlier move is absorbed before the next one begins. His schematic names the events along the way, from preliminary support to the last point of support, and groups them into phases A to E. Wyckoff Mapper applies that schematic to the chart's own bars, using bar volume against its time-of-day norm and ATR-scaled price moves to decide when each event has happened.
A dashed line at a climax means a range may be forming; the box appears once the automatic reaction confirms it, spanning the climax and the reaction. Event labels sit beyond the candles at the bar that confirmed each one. The strip under the range shows the phase letters from the bar each began, and the tag above names accumulation or distribution and, later, how the range ended. The corner panel lists the latest range's events as of the bar in view.
The map says where the chart stands in the schematic, not where price goes next. Events are recorded only once confirmed, so a swing-based event appears a few bars after its anchor and is never moved. The thresholds are provisional until tuned against labelled ranges; every one is a setting and rebuilds live, except the 1-minute days behind the volume norm, which need a reload.
Every setting, explained.
Read from the indicator's own settings, so this table always matches the current build.
| Group | Setting | What it does |
|---|---|---|
| Volume norm | Norm by time of day: sessions | Minute and second charts: the mean volume of the bars that closed at the same time of day over this many sessions before. |
| Rolling norm: bars | Range, tick and day charts: the mean volume of this many bars before. | |
| Samples needed | ||
| 1-minute days to start the norm from | Minute charts: the norm starts from the 1-minute days before the chart, so it is ready from the first bars - when this is more days than the chart loads (they are counted back from today). A change needs a reload. | |
| Range | ATR period (chart bars) | |
| Swing strength (bars each side) | ||
| Extended move (x ATR) | The close at least this far beyond the farthest close of the bars below. | |
| Extended move: bars back | ||
| Preliminary support / supply volume (x norm) | ||
| Climax: a new extreme of the prior bars | ||
| Climax range (x ATR, at least) | ||
| Climax volume (x norm, at least) | ||
| Automatic reaction within (bars) | ||
| Range expires after (bars) | ||
| Failed: a close beyond the climax by (x ATR) | After a spring: beyond the spring's extreme. | |
| Markup / markdown: beyond the range by (x its height) | After the sign of strength / weakness, a close this far beyond the range ends it (phase E). | |
| Events | Secondary test: within (x the range's height) of the climax | |
| Secondary test volume (x the climax's, below) | ||
| Spring / upthrust: back inside within (bars) | ||
| Spring / upthrust only after the secondary test | On: a dip under the climax before phase B is part of the secondary test (the textbook order). Off: a spring any time after the reaction. | |
| Test volume (x norm, below) | ||
| Sign of strength / weakness: a close beyond the range by (x ATR) | ||
| Sign of strength / weakness: bar range (x ATR, at least) | ||
| Back-up: within (x ATR) of the edge | ||
| Last point of support / supply: within (x the height) of the edge | ||
| Alerts | Alert on an event |
One license. Every tool.
Wyckoff Mapper is one of 76 tools in the Suite.